Take action
$375
Geiger counter Ludlum 3 with 44-9 pancake probe
0 Miles
Posted about 8 years ago in Orange, CA
Listed in categories:
Sold by
Get a second opinion
Chat securely on the app

SOLD
Additional images
Description
Because everyone needs their own geiger counter. The Apocolypse is coming In working condition is a used Ludlum model 3 ratemeter / survey meter with 44-9 probe (for alpha, betta and gamma radiation detection. The Ludlum Model 3 Survey Meter is the industry standard of radiation survey meters. The meter has a rugged design and microprocessor electronics. With proper care, the Ludlum Model 3 will last decades. It operates on two "D" cells for approximately 200 hours. The Ludlum Model 3 has adjustable high voltage to 1500 volts and includes external calibration controls. The four counting ranges are x0.1, x1, x10, x100. Typical Counting Range is from 0 - 200 mR/hr, or 0 - 500,000 cpm. The Ludlum Model 3 is supplied as shown with built-in speaker, strain relief cable, probe clip-on handle, two "D" cell batteries We opened to inspect internally and the unit is clean inside and out. INDICATED USE: General purpose survey COMPATIBLE DETECTORS: G-M, scintillation METER DIAL: 0 - 2 mR/hr, or 0 - 5k cpm, BAT TEST (others available) MULTIPLIERS: X0.1, X1, X10,X100 LINEARITY: Reading within ±10% of true value with detector connected CONNECTOR: Series "C" (others available) AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet) CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided) HIGH VOLTAGE: Adjustable from 200 - 1500 volts THRESHOLD: 30 mV ± 10 mV RESPONSE: Toggle switch for FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading RESET: Push-button to zero meter POWER: 2 each "D" cell batteries BATTERY LIFE: Typically greater than 2000 hours with alkaline batteries METER: 2.5" (6.4 cm) arc, 1 mA analog type CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint TEMPERATURE RANGE: -4°F(-20°C) to 122°F(50°C) INDICATED USE: alpha, beta, gamma survey; sample counting DETECTOR: pancake-type, halogen-quenched GM WINDOW: 1.7 + 0.3 mg/cm² mica WINDOW AREA: 15 cm² (2.3 in²) active, 12 cm² (1.9 in²) open EFFICIENCY (4π): 5%-14C; 22%-90Sr/90Y; 19%-99Tc; 32%-32P; 15%-239Pu, ≤ 1%-99mTc; 125I-0.2% SENSITIVITY (137Cs gamma): 3300 cpm/mR/hr ENERGY RESPONSE: energy dependant BACKGROUND: 60 cpm DEAD TIME: 80 microseconds OPERATING VOLTAGE: 900 Vdc CONNECTOR: series "C" (others available) INPUT SENSITIVITY: ≥ -30 mV CONSTRUCTION: aluminum housing with beige powder-coat finish TEMPERATURE RANGE: -15 to 50 °C (5 to 122 °F), may be certified for operation from -40 to 65 °C (-40 to 150 °F) SIZE: 4.6 x 6.9 x 27.2 cm (1.8 x 2.7 x 10.7 in.) (H x W x L) WEIGHT: 0.5 kg (1 lb)
Details
Condition
Good
Item location map
Map is approximate to keep seller’s location private.
Related searches
- Bmw
- Honda civic
- Chevy
- Chevy silverado
- Lexus
- Toyota tacoma
- Honda
- Ford
- Toyota
- Audi
- Nissan altima
- Jeep wrangler
- Jeep
- Mazda
- Ford ranger
- Truck
- Dodge
- Nissan
- Subaru
- Honda crv