Search For sale
Use the down arrow to enter the dropdown. Use the up and down arrows to move through the list, and enter to select. To remove the current item in the list, use the tab key to move to the remove button of the currently selected item. Use Escape to close the dropdown and return to the search box.
No results found
Navigate Categories by tabbing to the major areas. Use the Down key to open the subcategory and then use the Down key once more to enter it. Navigate the subcategory using the Up and down keys. Once on the subcategory you are interested in. Use the Enter key to navigate to that page.

Take action

$50

8145-00 Defrost Control

Posted almost 3 years ago in Portland, OR

Listed in categories:

Get a second opinion

Chat securely on the app

8145-00 Defrost Control

Additional images

Description

Description – Designed for commercial freezers and refrigerators, Paragon commercial defrost controls provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas and compressor off cycle. Time initiated, temperature or pressure terminated High-amp switch contacts, 40 amps, 2 hp Positive slider bar switch design, assures positive electrical contact and wipes the contact surface of contaminates Designed for defrost termination using an external temperature or pressure device Safety back-up- mechanical time-driven defrost termination Heavy-duty synchronous design drive motor Choice of three contact arrangements Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations Adjustable back-up defrost termination from 4 to 110 minutes in 2 minute increments Enclosure construction of heavy-duty steel with knockouts on the bottom, back and sides. Hasp and staple for padlock is part of the enclosure Time initiated, time terminated High-amp switch contacts, 40 amps, 2 hp Positive slider bar switch design, assures positive electrical contact and wipes the contact surface of contaminates Choice of three contact arrangements Heavy-duty synchronous design drive motor Adjustable frequency of defrost initiation from 1 to 6 cycles per day with a minimum of 4 hours between successive operations Adjustable defrost cycle from 4 to 110 minutes in 2 minute increments Accuracy of defrost duration is +/- 2 minutes Enclosure construction of heavy-duty steel with knockouts on the bottom, back and sides. Hasp and staple for padlock is part of the enclosure Hide Description

All content is available to screen readers from the outset. The See more button is for visual users only to expose content incrementally that is already available to you

Details

Condition

Used (normal wear)

All content is available to screen readers from the outset. The See more button is for visual users only to expose content incrementally that is already available to you

Item location map

Map is approximate to keep seller’s location private.