No results found
Use the down arrow to enter the dropdown. Use the up and down arrows to move through the list, and enter to select. To remove the current item in the list, use the tab key to move to the remove button of the currently selected item. Use Escape to close the dropdown and return to the search box.
Search For Sale
Navigate Categories by tabbing to the major areas. Use the Down key to open the subcategory and then use the Down key once more to enter it. Navigate the subcategory using the Up and down keys. Once on the subcategory you are interested in. Use the Enter key to navigate to that page.
The simpler way to buy and sell locally!

MR CARTOOL L202 R134a Digital Manifold Gauge Set HVAC for Testing Maintaining Air-Conditioner, Vacuum Pressure Temperature Leakage A/C Refrigeration

$55

Posted over 3 years ago in Bellflower, CA

Condition: Open Box (never used)

Listed in categories: Business equipment - Light industrial equipment & Tools

Chat securely on the app

Sold by

MR CARTOOL L202 R134a Digital Manifold Gauge Set HVAC for Testing Maintaining Air-Conditioner, Vacuum Pressure Temperature Leakage A/C Refrigeration

SOLD

Additional images

Description

MR CARTOOL L202 R134a Digital Manifold Gauge Set HVAC for Testing Maintaining Air-Conditioner, Vacuum Pressure Temperature Leakage A/C Refrigeration Tester with Built-in 90 Refrigerants Product details Brand MR CARTOOL Item Dimensions LxWxH 5.91 x 3.54 x 2.36 inches Item Weight 1.06 Pounds [Ideal A/C Maintaining Tool] MR CARTOOL L202 a/c manifold gauge adopts the most advanced digital circuit and the high precision pressure sensor(Accuracy: 0.5%). Widely used Automotive Air Conditioner, Household Air Conditioner, Refrigerating Chamber and Refrigeration Plant. Real-time test of pressure got relative temperature which can help you more convenient for refrigeration system installation or servicing.[Three Working Modes] R410a manifold gauge set comes with three common working modes: refrigerant pressure mode, vacuum percentage mode, leak detection mode. Equipped with real-time vacuum pressure test and percent indicate. Test range: 0 KPa~6000 KPa. Operating temp: -20℃~60℃(-4℉-140℉) , But the L202 cannot measure micron.[Built in 90 Refrigerants] MR CARTOOL L202 ac diagnostic manifold gauge set built-in 90 refrigerants and corresponding temperatures sheet data according to the US NIST standard.(R11 R13 R113 R114 R115 R116 R12 R123 R124 R125 R1270 R134A R14 R141B R142B R143A R152A R170 R21 R218 R22 R410A etc.)[Powerful Function] L202 a/c r134a manifold gauge set equipped with auto power off function, unit conversion and backlight function. By default,the system automatically powers down after 10 minutes of inactivity. Users can configure on cancel the auto power off function. The gauges are quite clear and readable. Short-press the button key to toggle the backlight on and off. Three Common Working Modes 407c refrigerant gauges comes with three common working modes: refrigerant pressure mode, vacuum percentage mode, leak detection mode. Press "+ " key and "— " key to switch different working modes. The corresponding position on the screen will flash when a certain content is selected. Refrigerant Measurement Mode Real-time displaying current vacuum pressure, temperature, and type of refrigerant. It is used for charging the refrigeration system with refrigerant, as well as real-time displaying current vacuum pressure, temperature, and type of refrigerant. Vacuum Measurement Mode Real-time display of current vacuum pressure and percentage of vacuum level. Note: 1. When setting the ultimate vacuum, press the "— " key to reset zero. 2. According to vacuumize result of 13L cylinder, LCD display"97%","98%"...after 3~5 minutes vacuumized. Higher percent means higher vacuum degree. 3. After vacuumize work finished,close manifold valve,remove vacuum pump. Leak Detection Mode Real-time display of current vacuum pressure, leak pressure and work time. Checking the LCD display pressure results,if pressure results are stable, that means there are no gas leak in refrigeration system and connections. If pressure results rising,that means somewhere is leaking in refrigeration system or connections. It should be maintained. Kindly Note: 1. Please operate according to the requirements of use manual or the guidance of professional personnel. 2. The digital gauge should be keept clean, the display screen should be bright and clear, so that the data on the display screen clearly.Use slightly alkaline detergent or soapy water to wash the case and connector. 3. The pressure gauge is perishable goods,need to checking regularly to ensure its accuracy. 4. Handled gently , to prevent shock and fall. 5. After use, please close all the button, to improve the service life. 6. Plug the joint when not use,to prevent foreign body from entering, clean and replace regularly refrigerant tube, remove dirt and impurities in valve. 7. If you encounter when you operate the low-pressure connection of the air-conditioning system to the refrigerant meter side port, the refrigerant meter does not read the air-conditioning system pressure, first disconnect the refrigerant meter, and then to press "-" button to zero cleaning. You will be able to use it again. 8. If you encounter not accurate pressures keep changing, first disconnect the refrigerant meter, and then to press "-" button to zero cleaning. You will be able to use it again.

All content is available to screen readers from the outset. The See more button is for visual users only to expose content incrementally that is already available to you

Take action

Item location map

Map is approximate to keep seller’s location private.

Related searches

  • Office chairs
  • Office furniture
  • Printer
  • Bobcat
  • Forklift
  • Filing cabinets
  • Excavator
  • Floor scrubber
  • Metal shelving
  • Rolling backpack
  • Ultrasonic cleaner
  • Dust mop